• "Limits"
– Torque and speed limits
The con
verter limit values are shown graphically and in a tabular form.
– "In-position" state
Dene the positioning window for the in-position monitoring function.
– Device supply voltage (only available for 400 V variants)
• "I/O conguration"
The conguration of the converter inputs and outputs is shown in a tabular form.
– In the table, a function can be assigned to an input or output of the terminal. Specied
functions can be selected.
– The analog inputs 0 and 1 have been dened for speed limit and torque limit respectively
by default. The corresponding elds are read-only.
– You can click the
icon to set the scaling and smoothing of functions assigned to the
analog inputs and outputs.
More information
For
more information about conguring setpoints, PTO, limits, and inputs/outputs, see Section
"Functions (Page225)"
7.4.2.3 Testing the converter conguration
Overview
After the quick setup, the web server allows you to test the converter conguration in jog mode
or continuous motion via the control panel.
Description of function
To test the conguration, the control panel must be open and the speed setpoint entered.
Commissioning (web server)
7.4Functions and menus