Corrective maintenance
12
12.1 Service and maintenance for the converter
12.1.1
Restor
ing the converter to factory settings
12.1.1.1 Restoring factory settings via a commissioning tool
Description
The restoring to factory settings with a commissioning tool (web server) only deletes the user-
speci󹪝c parameterization of the converter, for example motor data.
The following settings are retained with the restoring:
Activation and settings of User Management & Access Control
The "IP con󹪝guration" and "Device name" communication settings of the service interface
(X127)
Installed 󹪝rmware on the converter
The restoring to factory settings with the commissioning tool is described in Section "Restore
factory settings (Page209)".
12.1.1.2 Reset of all user-de󹪝ned settings to the factory setting via an SD card
Overview
The following user-de󹪝ned settings are stored in the converter:
Parameterization of the converter
Activation and settings of User Management & Access Control
"IP con󹪝guration" and "Device name" communication settings of the service interface (X127)
Self-generated certi󹪝cates
User-de󹪝ned parameter lists in the web server
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 481