Remedy: - Leave the STOP cam minus in the positive traversing direction and return the axis to the valid traversing range.
- Check the wiring of the S
TOP cam.
F52961 STOP cam plus reached
Message class: General drive fault (19)
Message value: -
Component: Control Unit (CU)
Response: OFF3
Acknowledgment: IMMEDIATELY
Cause: A 0 signal was detected at binector input, i.e. the STOP cam plus was reached.
F
or a neg
ativ
e tr
a
versing direction, the STOP cam plus was reached - i.e. the wiring of the STOP cam is incorrect.
Remedy: - Leave the STOP cam plus in the negative traversing direction and return the axis to the valid traversing range.
- Check the wiring of the S
TOP cam.