5.1.3.2 Dimension drawing and drilling dimensions for the 400 V converter
Dimension drawing
All dimensions are specied in millimeters.
:LGWK
'HSWK
+HLJKW
)6$)6%)6')6&
Table 5-2 Dimensions and mounting, 3AC400V, FSA...FSD, IP20
Frame size Width Height Depth Fixing
FSA 50 mm 180 mm 200 mm 2 x M4 / 2.5 Nm
FSB 60 mm 180 mm 200 mm
FSC 70 mm 180 mm 200 mm
FSD 95 mm 260 mm 230 mm 4 x M4 / 2.5 Nm
5.1.4 Minimum clearances
Description
Observe t
he following minimum mounting clearances. For converters without built-in fans,
install cooling fans above the converters for sucient heat dissipation.
Note
F
or conver
ters without built-in fans, when the surrounding temperature in the cabinet is ≥ 45 °C
(for 200V FSA:≥40°C), the airow velocity above the converters must be greater than
0.5m/s.
All dimensions are specied in millimeters.
Mounting
5.1Converter
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 97