You can select one of the following two values to dene the electronic gear ratio:
•
Number of PTO pulses per motor revolution (p4408).
• Gear ratio by using a numerator (p4410) and a denominator (p4409).
Note
When you use the numerator and t
he denominator to dene the electronic gear ratio, the
number of PTO pulses per motor revolution (p4408) must be set to 0. Otherwise, no
electronic gear ratio is active.
Note
When y
ou use t
he PT
O electr
onic g
ear function, the electronic gear is based on the encoder
resolution. The encoder resolution can be read from parameter r0979[2] and the default value
is 1024 ppr.
The range of electronic gear ratio is from 0.02 to 8000.
The electronic gear ratio can be set at servo-o state only.
Note
When you use the PTO electronic g
ear function, if the product of the PTO setpoint pulses per
motor revolution multiplied by the electronic gear ratio is not an integer, there is no zero mark
generated.
Parameters
The following list includes the par
ameters of the "PTO" function.
Number Name Unit
p4405 PTO maximum output frequency [kHz]
p4408 PTO pulse number
p4409 Gearbox encoder (motor)/PTO denominator (Control Unit)
p4410 Gearbox encoder (motor)/PTO numerator (Control Unit)
r4419 PTO diagnostics position setpoint
c4420 PTO position setpoint
p4422.0 PTO congur
ation
p4426 PTO zero mark
oset
9.4.6 Setting mot
or overload protection in accordance with UL 61800-5-1 Ed.2
Overview
The mo
tor overload protection function works without temperature sensors in the 1FL2 motors.
To comply with UL61800‑5‑1 Ed.2, you must make some additional settings when operating
the converter with a 1FL2 motor.
Functions
9.4General functions
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
242 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA