3RVLWLRQEHIRUHVPRRWKLQJ
3RVLWLRQDIWHUVPRRWKLQJ
7LPH
3RVLWLRQ
S
Figure9-2 Smoothing with PT1 lter
Parameter
s
The following list includes the par
ameters of the "Smoothing" function.
Number Name Unit
p29283[0...1] Pulse setpoint moving average time [ms]
p29284 Pulse setpoint PT1 lt
er time constant [ms]
9.5.6 Electr
onic gear ratio
Overview
Wit
h the function of electronic gear, you can dene the motor revolutions according to the
number of setpoint pulses, and sequentially dene the distance of mechanical movement. The
minimum traveling distance of load shaft corresponding to one setpoint pulse is called a length
unit (LU); for example, one pulse results in 1 μm movement.
Functions
9.5Fast position control with pulse train input (Fast PTI)
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 251