You can use the SDI Status panel for the following operations:
• Monitoring
The SINAMICS SDI S
tatus enters the monitoring mode when the servo state changes from
OFF to ON. In this mode, it displays the actual speed, actual torque, actual position, actual DC
link voltage, and position following error. You can press the DOWN button to navigate to the
next item.
• Diagnosis
The SINAMICS SDI Status enters the diagnosis mode when a new fault, alarm, or safety
message appears. You can press the OK button to acknowledge the faults after eliminating
the causes.
You can press the M button to switch between the monitoring mode and the diagnosis mode.
• Converter restart
You can press the key combination of the M button and the OK button for four seconds to
restart the converter.
11.1.2 Status display via LEDs
Description
The following tables explain the LED icons and states:
Table 11-1 Explanation of LED icons
LED Explanation
LED is ON.
LED is OFF.
LED ashes slowly.
LED ashes quickly.
LED ashes with variable freq
uency.
System messages
11.1SDI Status
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2