LED Explanation
V
LED 󹪞ashes in alternating order 3 times quickl
y - 2 s pause - ...
V
V
V
LED 󹪞ashes brie󹪞y every 3 s
Table 11-2 Signal states of RDY and COM LEDs during converter ramp-up and operation
RDY COM Description Remedy
Orange Orange
T
emporary state after the supply voltage is switched on
Restar
t
-
Green Green
Temporary state after the supply voltage is switched on:
󹪝rmware being loaded and initialized.
-
-
Green
Cyclic communication in progress -
Red
No 󹪝eldbus link:
No data exc
hange or con󹪝guration error
Data exchange lost
Data exchange in progress, but there are no setpoints
(controller in stop state)
Check message display and rectify
cause of fault.
Check operating mode of controller
(PLC).
Red
Converter signals a fault.
Firmwar
e error
Check message display, rectify cause of
fault.
Green
- Converter is ready for operation and error-free. -
Red
BIOS error:
General error
Loading error
File error:
SD card is not available or is faulty.
File corrupt
CRC error
Switch the converter supply voltage
o󹪜 and on.
Check SD card if available.
Reload 󹪝rmware.
Contact Hotline/Support.
System messages
11.1SDI Status
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 315