3.4.2.2 Setpoint cables and connectors
Description
The cable is used to connect the converter to a controller.
Table 3-8 Setpoint cables and connectors
Name Article number Length (m)
Option 1
Setpoint connector (50 pins) 6SL3260-2NA00-0VA0 -
Setpoint cable (50 pins) 6SL3260-4NA00-1VB0 1
Option 2
Setpoint cable with terminal block (50 pins) 6SL5562-0XX00-0AD0 0.5
More information
For more information about the se
tpoint cables and connectors, see Section "Interface
description - X132 (Page147)".
For more information about how to assemble the setpoint connectors, see Section
"Assembling the setpoint connector (Page738)".
3.4.3 Line 󹪝lters
Description
Line 󹪝lters limit the conducted interference emissions from the converters to the permissible
limit values according to IEC 61800-3 Category C2.
Line 󹪝lters are passive components used to expand the EMC properties of the servo drive
system.
Siemens recommends that you use a line 󹪝lter to protect the system from high frequency
noise.
Note
For applications in European Union, UK, and Kor
ea, the use of the recommended line 󹪝lters is
mandatory to ful󹪝ll the local EMC directives.
Note
The maximum length of the cable used to connect the line 󹪝lt
er to the converter is 3m.
Description
3.4Accessories
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 59