In the following cases it may be necessary to reset all user-de󹪝ned convert
er settings to the
factory setting:
The available credentials do not allow the necessary con󹪝guration of the converter (no
password for example).
Before recommissioning of the converter, for example if the application use of the converter
changes.
Before the converter is sold or disposed of, in order to erase all user-de󹪝ned settings.
Requirement
You can access the converter manually.
All electrical connections from the converter to the motor are disconnected.
You have an empty writable SD card with a maximum of 32 GB; e.g. 6SL5970-0AA00-0AA0.
Procedure
Proceed as follows to reset all user-de󹪝ned converter settings to the factory setting:
1. Create an empty 󹪝le called RESET.TXT in the root directory of the SD card.
2. Switch o󹪜 the supply voltage to the converter.
3. Wait until all the LEDS on the converter have gone out.
4. Insert the SD card into the converter.
5. Switch on the supply voltage to the converter.
6. The converter deletes the user-de󹪝ned settings.
7. The user-de󹪝ned settings are deleted.
8. Remove the SD card.
Result
All user-de󹪝ned converter settings are deleted.
The converter 󹪝rmware is unchanged.
After the manual reset to factory settings, access to the web server is possible via the service
interface (X127). For access via the service interface (X127), use the secure transmission
protocol HTTPS.