The following signals are assigned to the analog outputs by default.
Table 9-7 Default signals of analog outputs
Analog output Paramet
er Default signal
AO0 c0771[0] Actual speed smoothed
AO1 c0771[1] Torque actual value
S200 PTI uses a scaling characteristic to convert the value range -100%...100% of the
internal signal to the selected v
oltage range. The two points (x1, y1) and (x2, y2) dene the
scaling characteristic.
9
9ROWDJHRXWSXW99
S
[
S
\
S
[
S
\
S
More information
For more information about wiring analog outputs, see Section "Connecting t
he inputs and
outputs (Page147)".
Parameters
The following list includes the parameters of the "Analog outputs" function.
Number Name Unit
r0062 Speed setpoint after the lter [rpm]
r0063 Speed actual value smoothed [rpm]
r0070 A
ctual DC link voltage [V]
r0079[0...1] Torque setpoint total [Nm]
r0080 Torque actual value [Nm]
c0771[0...1] CU analog outputs signal
p29342 Reference frequency assigned to pulse input frequency
p29343 Reference frequency assigned to remaining number of pulses
r29350 Pulse input frequency
r29351 Remaining number of pulses
Functions
9.3Inputs/outputs
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
236 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA