Description of function
The droop pulse clearing is executed depending on the clearing mode selected via p29266.
• p29266 = 0: Clear droop pulses before enabling servo-on signal
3XOVHWUDLQVHWSRLQW
3RVLW
LRQVHWSRLQW
$FWXDOSRVLWLRQ
621
• p29266 = 1: Clear droop pulses before enabling serv
o-on signal or with the CLR high
level
3XOVHWUDLQVHWSRLQW
3RVLW
LRQVHWSRLQW
$FWXDOSRVLWLRQ
621
&/5
• p29266 = 2: Clear droop pulses before enabling serv
o-on signal or with the CLR rising
edge
3XOVHWUDLQVHWSRLQW
3RVLW
LRQVHWSRLQW
$FWXDOSRVLWLRQ
621
&/5
Parameters
The following list includes the par
ameters of the "Clearing droop pulses (CLR)" function.
Number Name Unit
p29266 Droop pulse clearing mode selection
c29267 Clear droop pulses
c29267 Clear droop pulses
Functions
9.5Fast position control with pulse train input (Fast PTI)
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 255