EasyManua.ls Logo

Siemens SINAMICS S200 - Page 475

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cause: A time slice over󹪞ow for t
he motor encoder has occurred.
Fault value (r0949, interpret hexadecimal):
yx hex: y = function involved (Siemens-internal fault diagnostics), x = time slice involved
x = 9:
Time slice over󹪞ow of the fast (current controller clock cycle) time slice.
x = A:
Time slice over󹪞ow of the average time slice.
x = C:
Time slice over󹪞ow of the slow time slice.
yx = 3E7:
Timeout when waiting for SYNO (e.g. unexpected return to non-cyclic operation).
Remedy: Increase the current controller sampling time
Note:
For a curr
ent controller sampling time = 31.25 µs, use an SMx20 with Article No. 6SL3055-0AA00-5xA3.
F31804 Motor encoder: Sensor Module checksum error
Message class: Hardware/software error (1)
Message value: %1
Component: Sensor Module Encoder 1
Response: ENCODER
Acknowledgment: POWER ON
Cause: A checksum error has occurred when reading-out the program memory on the Sensor Module.
F
ault v
alue (r0949, int
erpr
e
t hexadecimal):
yyyyxxxx hex
yyyy: Memory area involved.
xxxx: Di󹪜erence between the checksum at POWER ON and the actual checksum.
Remedy: - Carry out a POWER ON (switch-o󹪜/switch-on).
- Upgr
ade 󹪝rmware to later version.
- Check whether the permissible ambient temperature for the component is maintained.
F31805 Motor encoder: EEPROM checksum error
Message class: Hardware/software error (1)
Message value: %1
Component: Sensor Module Encoder 1
Response: ENCODER
Acknowledgment: IMMEDIATELY
Cause: Data in the EEPROM corrupted .
F
ault value (r0949, interpret hexadecimal):
01: EEPROM access error.
02: Too many blocks in the EEPROM.
Remedy: Replace the module.
F31813 Motor encoder: Hardware logic unit failed
Message class: Hardware/software error (1)
Message value: Fault cause: %1 bin
Component: Sensor Module Encoder 1
Response: ENCODER
Acknowledgment: PULSE INHIBIT
System messages
11.3Faults and alarms
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 473

Table of Contents