Cause: Error when operating the internal SPI bus.
Alarm v
alue (r2124, interpret he
xadecimal):
Only for internal Siemens troubleshooting.
Remedy: - Replace the Sensor Module.
- If required, upgr
ade the 󹪝rmware in the Sensor Module.
- Contact Technical Support.
A31903 Motor encoder: I2C-BUS error occurred
Message class: Hardware/software error (1)
Message value: %1
Component: Sensor Module Encoder 1
Response: NONE
Acknowledgment: NONE
Cause: Error when operating the internal I2C bus.
Alarm value (r2124, int
erpr
e
t he
x
adecimal):
Only for internal Siemens troubleshooting.
Remedy: - Replace the Sensor Module.
- If required, upgr
ade the 󹪝rmware in the Sensor Module.
- Contact Technical Support.
F31905 Motor encoder: Encoder parameterization error
Message class: Error in the parameterization / con󹪝gur
ation / commis
sioning pr
ocedur
e (18)
Mes
sage value: Parameter: %1, supplementary information: %2
Component: Sensor Module Encoder 1
Response: ENCODER
Acknowledgment: IMMEDIATELY
Cause: An error was identi󹪝ed in t
he encoder parameter
ization.
It is possible that the parameterized encoder type does not match the connected encoder.
Determine the parameter number using the fault value (r0949).
Fault value (r0949, interpret decimal):
yyyyxxxx dec: yyyy = supplementary information, xxxx = parameter
yyyy = 0:
No additional information available.
yyyy = 10:
The connected encoder is not supported.
Remedy: - Check whether the connected encoder type matches the encoder that has been parameterized.
- Correct the parame
ter speci󹪝ed by the fault value (r0949).
F31950 Motor encoder: Internal software error
Message class: Hardware/software error (1)
Message value: %1
Component: Sensor Module Encoder 1
Response: ENCODER
Acknowledgment: POWER ON
Cause: An internal software error has occurred.
F
ault value (r0949, interpre
t decimal):
The fault value contains information regarding the fault source.
Only for internal Siemens troubleshooting.