Response: OFF1
Acknowledgment: POWER ON
Cause: An internal software error has occurred.
F
ault value (r0949, interpret decimal):
Information about the fault source.
Only for internal Siemens troubleshooting.
Remedy: - If necessary, upgrade the 󹪝rmware in the Sensor Module t
o a later version.
- Contact Technical Support.
A32999 Encoder 2: Unknown alarm
Message class: Position/speed actual value incorrect or not available (11)
Message value: New message: %1
Component: Sensor Module Encoder 2
Response: NONE
Acknowledgment: NONE
Cause: An alarm has occurred on the Sensor Module for encoder 2, which cannot be interpreted by the converter 󹪝rm
w
ar
e.
This can occur if t
he
󹪝rmware on this component is more recent than the converter 󹪝rmware.
Alarm value (r2124, interpret decimal):
Alarm number.
Note:
If required, the signi󹪝cance of this new alarm can be read about in a more recent description of the converter.
Remedy: - Replace the 󹪝rmware on the Sensor Module b
y an older 󹪝rmware version.
- Upgrade the converter 󹪝rmware.
F33899 Encoder 3: Unknown fault
Message class: Position/speed actual value incorrect or not available (11)
Message value: New message: %1
Component: Sensor Module Encoder 3
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: A fault occurred on the Sensor Module for encoder 3, which cannot be interpreted by the converter 󹪝rm
ware.
This can occur if the
󹪝rmware on this component is more recent than the converter 󹪝rmware.
Fault value (r0949, interpret decimal):
Fault number.
Note:
If required, the signi󹪝cance of this new fault can be read about in a more recent description of the converter.
Remedy: - Replace the 󹪝rmware on the Sensor Module b
y an older 󹪝rmware version.
- Upgrade the converter 󹪝rmware.
A33999 Encoder 3: Unknown alarm
Message class: Position/speed actual value incorrect or not available (11)
Message value: New message: %1
Component: Sensor Module Encoder 3
Response: NONE
Acknowledgment: NONE
System messages
11.3Faults and alarms
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 477