EasyManua.ls Logo

Siemens SINAMICS S200 - Page 575

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13.3 Technical data of MOTION-CONNECT cables
13.3.1 Technical data of MO
TION-CONNECT 350
13.3.1.1 General technical data
Technical data
Table 13-63 General technical data of MOTION-CONNECT 350
Property MOTION-CONNECT 350
po
wer cable
MOTION-CONNECT 350 en‐
coder cable
MOTION-CONNECT 350
brake cable
Jacket material PVC PVC PVC
Number of conductors
With brake conductors:6
Without brak
e conduc‐
tors:4
6 2
Operating temperature (°C) -20...+80 -20...+80 -20...+80
Shielding Braided shield;
co
verage ≥ 85%
Br
aided shield;
coverage ≥ 85%
Braided shield;
coverage ≥ 85%
Oil resistance EN60811-2-1 EN60811-2-1 EN60811-2-1
Flame retardancy EN60332-1-1 to 1-3 EN60332-1-1 to 1-3 EN60332-1-1 to 1-3
Coolant resistance EN60811-2-1 EN60811-2-1 EN60811-2-1
Degree of protection (motor-
side onl
y)
IP65 IP65 IP65
Bending cy
cles 1 million 1 million 1 million
R
at
ed v
oltage U
0
/U (V)
200V converters:
300/1000
400V convert
ers:
600/1000
30/300 30/300
Technical data
13.3Technical data of MOTION-CONNECT cables
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 573