EasyManua.ls Logo

Siemens SINAMICS S200 - Page 607

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
p0300[0] Motor type selection
Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor data, Quick commissioning
Unit: -
Min:
0
Max:
10000
Factory setting:
0
Description: Selects the motor type or start to read in the motor parameters for a motor with self-identifying data (p0300 = 10000).
For p0300 < 10000 the following applies:
The 󹪝r
st digit of the parameter value always de󹪝nes the general motor type and corresponds to the third-party motor
belonging to a motor list:
2 = rotating synchronous motor
Value: 0: No motor
2: Synchronous motor
2120: 1FL2 synchronous motor
10000: Motor with data set
Dependency: See also: p0301
p0301[0] Motor code number selection
Data type: U
nsigned32 V
isible in: S
t
andar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor data, Quick commissioning
Unit: -
Min:
0
Max:
99999999
Factory setting:
0
Description: Code number of the connected motor, whose data was accepted when commissioning.
Dependency: Code numbers are only possible for motor types that correspond to the motor type selected in p0300.
See also: p0300
Note
For a mot
or with self-identifying data, p0301 cannot be changed. p0301 is automatically written to the code number
of the motor parameter read in (r0302) if p0300 is set to 10000. For other values, the commissioning routine cannot be
exited.
r0302[0] Motor code (identi󹪝ed)
Data type: Unsigned32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Motor data, Quick commissioning
Unit: -
Description: Displays the identi󹪝ed motor code number.
When the dr
ive powers up, the motor code is read out the motor. For r0302 = 0, the motor data were not identi󹪝ed.
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 605

Table of Contents

Other manuals for Siemens SINAMICS S200

Related product manuals