r9728 SI actual checksum conguration of the safety functions
S200 PTI Dat
a type: Unsigned32 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Extended functions
Unit: -
Description: Displays the checksum over the checked parameters used to congure safety functions (actual chec
ksum).
Dependency: See also: p9729
p9729 SI reference checksum conguration of the safety functions
S200 PTI Data type: Unsigned32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tate:
Commissioning (Safety Integrated)
Parameter group: Extended functions
Unit: -
Min:
0000 he
x
Max:
FFFF FFFF hex
Factory se
tting:
A1A1 A1A1 hex
Description: Sets the checksum over the checked parameters used to congure safety functions (ref
erence checksum).
Dependency: See also: r9728
r9750[0...63].0...20 SI diagnostic attributes
Data type: Unsigned32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Extended functions
Unit: -
Description: Displays the diagnostic attributes of the safety messages that have occurred.
Bit array: Bit Signal name 1 signal 0 signal
00 Hardware replacement recommended Yes No
15 Message has gone Yes No
16 PROFIdrive fault class bit 0 High Low
17 PROFIdrive fault class bit 1 High Low
18 PROFIdrive fault class bit 2 High Low
19 PROFIdrive fault class bit 3 High Low
20 PROFIdrive fault class bit 4 High Low
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
694 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA