r60048[0...63] SI message time received in milliseconds
S200 PTI Data type: Unsigned32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Extended functions
Unit: ms
Description: Displays the relative system runtime in milliseconds when the safety message occurred.
Dependency: See also: r9753, r9754, r9755, r9756, r60044, r60045, r60049, p60052
r60049[0...63] SI message value
S200 PTI Data type: Int
eg
er32 V
isible in: Ext
ended displa
y
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Extended functions
Unit: -
Description: Displays the additional information about the safety message that occurred (as integer number).
Dependency: See also: r9753, r9754, r9755, r9756, r60044, r60045, r60048, p60052
p60052 SI message cases counter
S200 PTI Data type: Unsigned16 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Can be
changed in the operating
state:
Operation
Par
ameter group: Extended functions
Unit: -
Min:
0
Max:
65535
Factory setting:
0
Description: Number of safety message cases that have occurred since the last reset.
Dependency: The safety message bu󹪜er is cleared by resetting t
he parameter to 0.
See also: r9753, r9754, r9755, r9756, r60044, r60045, r60048, r60049