Restrictions:
In the event of changes of distributed programs on the local drive using the Editor, it should
be noted that only the channel states are monitored on the NCU currently connected. If the
program is still interrupted or active on another NCU, it cannot be correctly distributed after
the change.
The display of the active block, the marking of the block search as well as the read-only
handling of the program opened in the Editor are executed only for the active programs of
the currently connected NCU.
In the Editor, programs are always opened in the context of the currently connected NCU.
This can lead to a faulty step recognition with distributed programs.
In the current block display in the "Machine" operating area, you can display only the active/
distributed programs of the currently connected NCU.
The simulation of job lists via several machines is not possible.
If distributeJoblist=true is configured in the systemconfiguration.ini file, then part
or subprograms can no longer be selected via the "Program Manager" operating area.
Channel menu
6.7 Distribution via job lists in the case of 1:N
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 93

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals