5.5 Example 3: Assigning the Variable Type, Default, System or User
Variable, Input/Output Field Position properties
Example 3
The following example defines a variable for which the properties variable type, default setting,
system or user variable and position are set.
DEF Var3 = (R//10////"$R[1]"//300,10,200//)
Variable type: REAL
Default setting: 10
System or user variable: $R[1] (R-Parameter 1)
Position of short text: Default position in relation to input/output field
Position of input/output field:
Distance from left: 300
Distance from top: 10
Width: 200