Alarm display
MSG ALARM Date/time
No. Deletion criterion Text
DETAILS
Entry Description
MSG
ALARM Type of alarm: ALARM_ON, ALARM_OFF, ALARM_ACK
Date/time Data and time of the event
No. Alarm number
Deletion criterion: Information as to how the alarm was acknowledged
AUTOMATIC Automatic acknowledgement
POWER ON Acknowledgement using PowerOn
RESET Acknowledgement using NCK reset
NC START Acknowledgement using NC start
NC RESET Acknowledgement using NC reset
ALARM CANCEL Acknowledgement using Alarm Cancel key
RECALL Acknowledgement using the Recall key
HMI Acknowledgement using HMI
PLC Acknowledgement using PLC
Text Display of the English alarm text
DETAILS If additional information regarding an entry is known.
Example
MSG ALARM_ON 20.02.2009 14:25:37
8020 POWER ON : Option 'activation of more than 1 channels' not
set
DETAILS:
Mode: JOG Program: canceled Channel: interrupted
Program-Level information:
Level Program running: Invoc Offset
1 /_N_MPF0 0 0
18.7.6 Advanced settings
You define the size of the log file of the action log in the "actlog.ini" configuration file.
Service and diagnostics
18.7 Action log
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 445