Machine data:
MD11280 $MN_WPD_INI_MODE
Processing mode of ini files in the workpiece directory
= 1 When the NC is started for the first time, after the workpiece selection, ini files with the name
of the selected part program and the following extensions are executed:
CEC Sag compensation (Cross Error Compensation)
GUD User data (Global User Data)
PRO Protection zones
RPA R parameters
SEA Value assignments (Setting Data Active)
TMA Magazine data (Tool Magazine Active)
TOA Tool offsets (Tool Offset Active)
UFR Work offsets (User Frame)
16.10 Network settings
Activate
By default, the network settings cannot be backed up. The archiving of the network settings
must be enabled:
1. Copy the "slpmconfig.ini" file from the /siemens/sinumerik/hmi/template/cfg directory.
2. Store the file in the /oem/sinumerik/hmi/cfg or /user/sinumerik/hmi/cfg directory.
3. Open the file and enter the following for [SeriesSetup]:
SupportNetworkSettings=true
4. Restart SINUMERIK Operate.
Note
This setting also affects the creation of a complete standard archive using Ctrl+Alt+S or Ctrl
+Alt+C.
Restrictions
● The leases files are not saved:
– /system/etc/udhcpd-eth0.leases
– /system/etc/udhcpd-ibn0.leases
● A configuration in the system network must be based on the DNS name rather than IP
addresses.
Data backup
16.10 Network settings
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 369