"sc disable usb" locks USB storage devices: Specifically, the devices of USB class "storage"
are involved, i.e. input devices can still be operated at the USB interface.
● Without a time specification [-MINUTES] , a permanent disable is set. When a time is
specified, the inhibit is specified in minutes.
● The inhibit can refer to all network participants of the system network or a list with host
names or IP addresses can be specified, for which the inhibit is valid.
2.5.7 Disconnect
Description
Syntax: sc disconnect MOUNTPOINT
sc disconnect all
Alternative names: umount, unmount
Authorization level: user
The "sc disconnect" command terminates the connection to a remote file system previously
connected using "sc connect". If the MOUNTPOINT was created automatically by 'sc', the
associated directory is also deleted again.
The "sc disconnect -all" variant can be used to remove all existing SMB and NFS file systems.
2.5.8 Distribute
Description
Syntax: sc distribute [parameter]
Alternative names: dist
Authorization level: service
This command distributes TCU data to other machines in the system network. Only the
"tcudata" parameter is relevant here.
distribute tcudata
Syntax: sc distribute tcudata
Alternative names: ---
Authorization level: service
This command informs the active DHCP server that TCU data in /user/common/tcu has been
manually changed. The server can then distribute this data to the standby servers.
Configuring the system
2.5 Description of the actions
NCU operating system