Backing up and restoring data
4.12 Operating a service PC/PC in the network
PCU-Basesoftware (IM8)
108 Commissioning Manual, 02/2014, 6FC5397-1DP40-4BA0
Configuration with PG/PC and switch to PCU
Figure 4-10 Connecting a PG via a switch to a PCU
Note
If a PCU is switched off and on again without its own OP/TP including TCU, and if the PCU
boot
-up is intended to be performed from the service system (EBS), an external VGA
monitor and keyboard are needed to operate the PCU.
An external VGA monitor and keyboard are not needed if the TCUs are operating and the
PCU is not switched off with the EBS during b
ooting.
On the PG/PC with Windows 7:
● Connecting a PG/PC to a PCU according to one of the configurations shown above.
● The network protocol used is: TCP/IP.
TCP/IP is already preconfigured on the PCU.
● Setting up IP addresses on the same subnetwork.
● Releasing a directory on the PG/PC for network access.
On the PCU in the Service Center (WinPE):
● On the PCU start the Service Center (WinPE).
● Establish a network connection to the shared directory of the PG/PC.
See: Functions of the Service Center (Page 88)