Entries Meaning
NewToolFavoritesOnly Refers to the "New tool" function.
True - only those tool types that are configured as favorites
are listed.
False - default setting, all tool types are listed.
SortationInFirstEtcLevel True - the "Sorting" function is placed at the first softkey
level. The "Continue" function is omitted.
False - default setting, sorting at all softkey levels.
ToolBufferOnceOnTop True - default setting, buffer is displayed at the start of the
list.
False - buffer is displayed for each magazine. Only those
locations are displayed that are assigned to the magazine.
UnloadToolFromLoadPlaceEnabled True - a tool at the load station can be removed from the
load station using the "Unload" softkey.
False - default setting. The "Unload" softkey is not displayed
for a tool at the load position.
CreateNewToolWithCuttPos9Enabled True - cutting edge position 9 is offered in the cutting edge
position selection.
True - default setting, cutting edge position 9 is not offered
in the cutting edge position selection.
AutoHNumberDisplayEnabled Column of the cutting edge parameter "IsoHNoDPH - ISO
H number" depending on the machine configuration.
True - default setting, the column is automatically displayed.
False - the column is not automatically displayed.
AutoUniqueDNumberDisplayEnabled Column of the cutting edge parameter "UniqueDNo" de‐
pending on the machine configuration.
True - default setting, the column is automatically displayed.
False - the column is not automatically displayed.
AccessLevelDeleteAllDNos The following entry specifies the access level as of which
the "Delete all D numbers delete" function is offered.
Default setting: Access level 3 (user) - relevant only when
the "Unique D number" setting has been made.
MagazineNumberOfDCheckAndActivate Default setting: -2 - the tools of all magazines are considered
by the function "Check for unique D number and activate
tool."
>0 - The above function only considers the tools of the
named magazine.
AutoFixedPlaceDisplayEnabled Column of the tool parameter "ToolStateFixed" - tool status
- tool is fixed-location coded and acts dependent on the
magazine configuration.
True - default setting, the column is automatically hidden, if
all of the configured magazines are fixed location coded.
False - the column is not automatically hidden.
MagPlaceAdapterDisplayEnabled Columns of the magazine location adapter parameters are
displayed in the "Magazine" window.
False - default setting, parameters are not displayed.
Tool management
12.2 Configuring the user interface
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 173