Rampup function generator quick stop
The status display for the ramp-function generator quick stop corresponds to the interface
signal:
DB31, ... DBX92.1 "Ramp-function generator disable active".
Status Meaning Display
1 Ramp-up function generator quick stop is active. The drive is stopped without
a ramp function with speed setpoint = 0 and without pulse suppression.
Yes
0 Ramp-up function generator quick stop is not active for the drive. No
Pulses enabled
The message whether the pulses have been enabled for the drive corresponds to the interface
signal:
DB31, ... DBX93.7 "Pulses enabled".
Status Meaning Display
1 The drive module pulses are enabled. The axis/spindle can now be traversed. Yes
0 The drive module pulses are suppressed. The axis/spindle can therefore not
be traversed.
No
Drive ready
The display of the current status of the selected drive corresponds to the interface signal:
DB31, ... DBX93.5 "Drive ready".
Status Meaning Display
1 The drive is ready. Yes
0 The drive is not ready. No
Ramp-up phase
The display of the current ramp-up phase of the selected drive corresponds to the drive
parameter:
r0002 "Drive operating display".
Number of faulty signs-of-life
Display of communications errors detected in hardware between NC and drive.
Note
If the display shows a value other than "0", please contact your Siemens regional office!
Service and diagnostics
18.2 Displaying the Service overview
SINUMERIK Operate (IM9)
420 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1