Check that:
the tted tool is the one required for the operation in progress.
the length of the tool in use is that set up in the list of cutters
(CALIBRATION -> F2 menu)
ERROR 8
Tool too long or not properly
installed!
The password entered is wrong. Check that you have entered the
password issued by SILCA or apply to SILCA for a password.
ERROR 9
The number of aempts have
been exceeded!
Restart the machine.
The problem occurs after replacing the machine mother board.
The machine memory has no MACHINE ID. Use the WinTransfer/
SRS program to do a CONNECTION TEST.
ERROR 10
Machine ID not set!
See operang manual.
An error has occurred when calculating the cuts or searching by
code. Make a note of the error and the condition which caused it and
advise After-Sales Service.
ERROR 43
INTERNAL ERROR
Error in searching data or in
cung calculaon.
See code:
An error has occurred in calculating the engraving path. Make a note
of the error and the condition which caused it and advise After-Sales
Service.
ERROR 13
Error in calculang
engraving process!
Code:
Error in loading data onto the machine with the USB-PEN. Please
repeat the operation to reload the data onto the USB-PEN. If the
error persists, make a note of it and the condition which caused it
and advise After-Sales Service.
ERROR 16
Error during data updang
procedure via USB PEN.
Error code:
The message indicates that the machine has skipped some steps
during the job.
The user should check the key just cut and if necessary repeat
the entire cutting process for the last key cut.
ERROR 17
Loss of steps detected!
Repeat this job?
No=STOP Yes=ENTER