7.2 ERROR MESSAGES
General message.
ERROR XX
INTERNAL ERROR
. . .
The message warns that the machine has reached a Z axis
measurement over the limit allowed.
If the problem persists contact After-Sales Service.
ERROR 1
Depth limit exceeded!
The machine automatic calibration procedure has read adjustment
values exceeding the tolerance established by SILCA. Repeat the
procedure and pay attention to all the operations required. If the
problem persists contact After-Sales Service.
ERROR 2
Tolerance limit exceeded
during calibraon.
Repeat the operaon.
See operang manual.
The spindle rotation release lever is out of line.
ERROR 3
Check tool installaon and
stop lever posion!
A wrong operation has been performed in one of the machine
calibration procedures:
Machine zeros
Clamp calibration
Detection of cutting/decoding plate with a clamp different from the
one required.
ERROR 4
ERROR Z AXIS
No contact made!
ERROR 5
ERROR X AXIS
No contact made!
ERROR 6
ERROR Y AXIS
No contact made!
The machine has detected an unexpected contact during a
movement. The causes could be:
An obstacle during a movement: remove the obstacle
A long offcut is creating a bridge between the tool and the tted
key: clean all the swarf off the machine and repeat the operation.
An offcut is creating a bridge between the TRACER TOWER and
the machine: carefully clean any swarf off the TRACER TOWER.
ERROR 7
Faulty contact made.
Press START to reset axes!
Operating manual TRIAX PRO