It is important to replace the battery as allows LOG events to be
saved with the right date/time.
ALARM 12
Flat clock baery:
see operang manual for
replacement.
Download a more up-to-date SW version.
ALARM 13
Machine rmware is more
up to date than the soware
in the USB PEN !
7.3.1 MESSAGES ABOUT SPINDLE
The message indicates that there is no connection between the
mother board and driver board.
The problem could be caused by: the mother board; the connection
cable between the mother board and spindle driver boar; the spindle
driver board, the safety microswitch or the fuses on the motor circuit
board.
ALARM 5
SPINDLE DRIVER ALARM
No communicaon between mother
board and spindle drive.
See operang manual
Eect :
Motor not turning
ALARM 6
SPINDLE DRIVER ALARM
Spindle speed not detected :
motor locked
See operang manual
Cause :
Short circuit on spindle motor or board power loss.
Driver damaged.
Check AZ motor board connectors
Eect :
Free-running motor does not reach the rotaon speed
required for cung.
ALARM 7
SPINDLE ALARM
Spindle rpm not reached aer
acvaon!
See operang manual
Cause :
Motor not working
Driver board not working
Driver board with wrong parameters.
A fuse on the motor circuit board cut out
Eect :
Motor under excessive strain during cutting.
ALARM 8
SPINDLE ALARM
Excessive cuer strain during
cung!
See operang manual
Cause :
Cutter does not cut
The combination rpm/cutting speed is not compatible:
select a more suitable combination
Generic alarm relating to the spindle driver board.
Check fuses on the motor circuit board.
If the problem persists contact After-Sales Service.
ALARM 4
SPINDLE DRIVER ALARM
Code: 00000000
See operang manual
[ENTER] to reset alarm
Operating manual TRIAX PRO
Copyright Silca 2016
79