Note
TheMotorControlUnitmustneverbephysicallydismounted
fromtheHullUnit.
Hullunitmountingprocedure
Tomakesurethattheprocedureisfollowed,tickoffeachtask
afterithasbeendone.
1
Useatackletolowerthehullunit(withthetransducer
protectioninplace)intothesonarroom
2Removetheblindcoverfromthetrunkandcheckthat
thegasketisnotdamaged.
3
Storetheblindcoverinthesonarroomforpossible
futureuse.
4Removethetransducerprotectionandlowerthehull
unitcarefullyontothetrunk.
5
Tightentheangenutswithatorqueofapproximately
470Nm.(OntheSX95hullunit,use140Nm.)
6Keepthetransducercableandconnectordry,and
handlethemwithgreatcaretopreventmechanicaldamage.
46
307531/C