C4 User Manual
October 25, 2021 ©2021 Smartrise Engineering, Inc. All Rights Reserved Page 249
29.13.1 Disable OSS
The Disable OOS feature prevents the car from ever going into the Out of Service mode of
operation or faulting out with OOS regardless of the Hourly Fault Limit or OOS input being
active.
The following procedure describes how to disable OSS.
1. Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 58.
2. From the MISCELLANEOUS menu, scroll and select OOS.
Figure 445: MISCELLANEOUS Menu – OOS
3. From the OOS menu, scroll and select Disable OOS.
Figure 446: OOS Menu – Disable OOS
4. From the DISABLE OOS menu, scroll and select if out of service is disabled.
Figure 447: DISABLE OOS Menu
5. Scroll right and press Save.
29.13.2 Hourly Fault Limit
The hourly fault limit is the number of faults allowed per hour prior to the car going out of
service. The car remains out of service until the hour window elapses.
The following procedure describes how to set hourly fault limit.
1. Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 58.
2. From the MISCELLANEOUS menu, scroll and select OOS. See Figure 445.

Table of Contents

Other manuals for Smartrise C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise C4 and is the answer not in the manual?

Smartrise C4 Specifications

General IconGeneral
Controller TypeElevator Controller
Microprocessor32-bit
Communication ProtocolCANbus
Input Voltage120/240 VAC
Frequency50/60 Hz
Number of Floors Supported64
ManufacturerSmartrise
ModelSmartrise C4

Related product manuals