Chapter 22 DCU Setup (DCU)
1232
GPI Output Setting (GPI Output Assign Menu)
a) 1: Field 1, 2: Field 2, 3: Any
When “ ” is selected as the trigger polarity, there is no Pulse Width
setting. When “Status” is selected, there is no Pulse Width or Timing
setting.
4
In the <Source Device> group, select the control panel or DCU to handle
the GPI output.
SCU1: ID1 control panel (PNL1)
SCU2: ID2 control panel (PNL2)
SCU3: ID3 control panel (PNL3)
DCU1: ID1 DCU
DCU2: ID2 DCU
When the action set in the following step 5 is carried out on the control
panel selected here, this causes a GPI output. It is also possible to output
error information. When the DCU is selected, you can output error
information by means of the action set in step 5.
5
Using any of the following methods, select the action you want to set.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video cursor.
Turn the knobs.
a) • Action list when the trigger type is other than “Status”
(In M/E-x, the x is the M/E bank number (1 to 4); in Keyx the x is the key number (1
to 8); in DSKx the x is the DSK number (1 to 8)).
When Source Device is SCU: M/E-x Keyx SS ? Recall, P/P DSKx SS ? Recall, Editor
GPI-?? (only when BZS-8050 license is valid), No Action
When Source Device is DCU: No Action
Action list when the trigger type is “Status”
(In M/E-x, the x is the M/E bank number (1 to 4); in Keyx the x is the key number (1
to 8); in DSKx the x is the DSK number (1 to 8)).
When Source Device is SCU: M/E-x Keyx SS ? Recall, P/P DSKx SS ? Recall, M/E-
x Keyx On, P/P DSKx On, Error Make, Error Break, Keep Make, Keep Break,
Device Recording, No Action
When Source Device is DCU: Error Make, Error Break, No Action
b) When knob 2 selection is “Key Snapshot”
Knob Parameter Adjustment Setting values
3 Pulse Width Pulse width 1 to 60 (fields)
4 Timing Output timing
1 to 3
a)
Knob Parameter Adjustment Setting values
2 Action Action selection
1 and upwards
a)
5 Reg No Snapshot register number
1 to 4
b)
5 GPI No GPI number selection
1 to 32
c)