Sony MVS -8000X - Assigning Keys to the DSK1 and DSK2 Buttons in the Downstream Key Fade-To-Black Control Block

Sony MVS -8000X
1310 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 19 Control Panel Setup (Panel)
1098
Overall Control Panel Settings (Config Menu)
Assigning Keys to the DSK1 and DSK2 Buttons in the
Downstream Key/Fade-to-Black Control Block
It is possible to select the key used for downstream key/fade-to-black control
block operations.
For details of the downstream key/fade-to-black control block, see Chapter 2
(Volume 1).
1
In the Panel >Config >Link/Program Button menu, press [DSK/FTB
Module].
The DSK/FTB Module menu appears.
The left side of the status area shows the DSK1 and DSK2 buttons, and the
right side shows a list of keys to be assigned.
2
Press the indication (DSK1, DSK2) of the button for the assignment.
The button you pressed changes to reverse video.
3
Using any of the following methods, select the key to be assigned.
Press directly on the list.
Press the arrow keys to scroll the reverse video cursor.
Turn the knob.
4
Press [Set], to confirm the selection.
This assigns the selected key to the key delegation button.
To return the key delegation button assignment to the factory
default state
In the DSK/FTB Module menu, press [Default].
This returns the key delegation assignment to the factory default state.
Assigning Keys to the Independent Key Transition
Control Block (Simple Type)
It is possible to select the keys that can be used in an independent key transition
control block (simple type) operation.
Knob Parameter Adjustment Setting values
1 Key No Selection of key assigned to
button
1 to 40