Chapter 22 DCU Setup (DCU)
1235
Serial Port Settings (Serial Port Assign Menu)
6. Simple VDCP: disk recorder with low-performance communications (video disk
communications protocol)
7. Extended VTR (Abekas A53 protocol)
8. Mixer ESAM-II
9. AS ES-BUS: device supporting the AS ES bus protocol
Notes
Mixer ESAM-II cannot be operated from this system. It can only be
operated from an editing keyboard.
4
Press [Device Type Set].
The selected protocol is reflected on the left of the status area.
5
To enter the name of the serial port, press [Set] in the <Name> group.
A keyboard window appears. You can enter a name of not more than 16
characters.
If no name is set for the serial port, it is displayed as “DCUd_PORTs-p.”
d: 1 or 2 (DCU No.)
s: 2 to 6 (Slot No.)
p: 1 to 6 (Port No.)
6
Press [Enter].
To return the set name to the default name
Press [Clear] in the <Name> group.
7
From the <SCU Select> group, select the control panel (SCU1, SCU2 or
SCU3) assigned to operations on the external device connected to the
serial port.
Deleting the serial port assignment
1
In the DCU >Serial Port Assign menu, select the target for the setting
(DCU1 or DCU2) from the <DCU Select> group.
2
Using any of the following methods, specify the serial port.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video cursor.
Turn the knob.
a) The range of setting values depends on the DCU port setting. (When the MKS-2700 is
connected, select 2 for the slot and a value in the range 1 to 6 for the port.)
Knob Parameter Adjustment Setting values
1 Port No Serial port
1 and upwards
a)

Table of Contents

Other manuals for Sony MVS -8000X