Chapter 3 Signal Selection and Transitions
199
Independent Key Transitions
1
In the Multifunction Flexi Pad control block, press the [TRANS RATE]
button.
The Multifunction Flexi Pad control block switches to the transition rate
setting mode.
2
In the region selection buttons, select the switcher bank.
3
Press the [TRANS SEL] button in the memory recall section.
You can select the type of transition for which to set the rate.
4
Press the [KEY1] button.
This enables setting of the independent key transition rate for M/E-1 key1.
5
Watching the alphanumeric display, enter the transition rate you want to
set with the memory recall section button.
If required, press the [TC] button to switch the input mode (frame count
input or timecode input).
• Enter a value of up to three digits.
• To cancel the input, press any of the mode selection buttons.
6
Press the [ENTR] button.
Setting the independent key transition rate by a menu operation
1
In the M/E or PGM/PST menu, select first the desired one from VF1
‘Key1’ to VF4 ‘Key4,’ then HF6 ‘Transition.’
The Transition menu for the selected key appears.
2
Select any transition type in the <Transition Type> group.
If, in the Setup menus, you set insertion/deletion as independent modes,
make the settings for insertion in the <On Transition Type> group, and the
settings for deletion in the <Off Transition Type> group.
3
Turn the knob to set the transition rate.
Knob Parameter Adjustment Setting values
1 Transition Rate Transition rate 0 to 999 (frame count)