Chapter 10 Special Functions
484
Multi Program 2
1
In the status area of the Engineering Setup >Panel >Config >MP2 Main/
Sub Assign menu, select 1st Row (M/E-1), then press [Main] in the <Main/
Sub Assign> group.
2
Press [Dual M/E Assign] to assign M/E to two banks.
In this state, both 1st Row and 2nd Row are set to main.
3
Set 2nd Row to [Sub].
This cancels the shift/non-shift assignment for dual M/E in standard mode.
Notes
It is not possible to assign the combinations of Main with Main&Sub, or Sub
with Main&Sub.
Assigning the [MAIN] and [SUB] delegation buttons to buttons
on the control panel
To assign the Main/Sub switching function to buttons in the
transition control block
This applies to the standard type and compact type transition control block, and
the CCP-6224/6324 control panel.
For details of the transition control block, see page 59 (for the standard type)
or page 104 (for the compact type).
For details of the CCP-6224 2M/E control panel, see page 107, and for the
details of the CCP-6324 3M/E control panel, see page 107.
1
In the Engineering Setup >Panel >Config menu, press [Program Button].
The Program Button menu appears.
2
Press [Transition Module 1].
The Transition Module 1 menu appears.
3
Select the switcher bank in the <Bank Select> group.
The buttons in the transition control block on the left appear in the
currently assigned state.
4
Press the button whose assignment you wish to change.
The button you press appears in reverse video.