097-93100-01 Revision C – February, 2010 TimeCreator 1000 User’s Guide 107
Chapter 5 Provisioning
Provisioning Alarms
To enable the alarm for IOC in holdover for extended period (alarm type of EXTHOLD),
perform the following steps
:
1. Login at the Admin or Power-User level (see Login, on page 74).
2. Type
set alarm-state exthold enable and press Enter.
Table 5-7. TimeCreator 1000 Alarm Codes
Alarm Code Description
IOCFAIL
IOC card failure
IMCFAIL
IMC card failure
IMCCOM
IMC communication failure
IOCCOM
IOC communication failure
OUTDISC
DTI output disconnect
INPDISC
DTI input disconnect
INPCBLADV DTI input cable advance invalid
INPUNSTBL
DTI input performance unstable
INPDISQ
DTI Input disqualified
IOCINCOMP
IOC cardss are incompatible
IMCINCOMP
IMC and IOC are incompatible
EXTHOLD
IOC in holdover for extended period
GPSCOMM
GPS communications failure
MTIET
MTIE-t threshold exceeded
MTIE35
MTIE-35 threshold exceeded
PPJITTER
PP-jitter threshold exceeded
FER
Frame error rate threshold exceeded
PWROUTPUT
Power module output failure
PWRFAN
Power module fan failure
IOCRMV
Both IOC removed
JAMSYNC
Jam sync required
XSYNC
Sync signal between IOC failed