097-93100-01 Revision C – February, 2010 TimeCreator 1000 Users Guide 131
Appendix A Alarms, Events and SNMP Traps
Alarm Messages
Table A-2. System Notification Messages - Alarms
Index
Trap Name
(trapID)
Severity
(default)
Trap Messages
(trapDescription)
Description
Corrective
Action
1 IMCNCOM Critical IMC-IOC <#>
communication
failed
Indicates that
communication
between IOC
and IMC has
failed
If problem
persists, check
IMC and IOC
modules for
alarms. If module
has failed, re-seat,
if issue is not
resolved, replace
module.
IMC-IOC <#>
communication
restored
Indicates that
communication
between IOC
and IMC has
been restored
No action required
2 IOCNCOM Critical Inter-IOC
communication
failed
Indicates that
communication
between
redundant IOC
modules has
failed
If problem
persists, check
IOC modules for
alarms. If IOC has
failed, re-seat, if
issue is not is
resolved, replace
module.
Inter-IOC
communication
restored
Indicates that
communication
between
redundant IOC
modules has
been restored
No action required
3 CARDFAIL Critical IOC <#>
operational
failure
Indicates that
the specified
IOC module is
not functioning
properly
Re-seat the IOC
module, if issue
not resolved,
replace module
IOC <#>
recovered from
operational
failure
Indicates that
the specified
IOC module is
now functioning
properly
No action required

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals