290 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix D Specifications and Factory Defaults
Factory Defaults
Alarm Default Values
Local Command Log Buffer
Size
100 0 to 100 kbytes
Local Security Log Buffer Size 100 0 to 100 kbytes
Local NTP Log Buffer Size 100 0 to 100 kbytes
Local Performance Log Buffer
Size
100 0 to 100 kbytes
Performance Log Interval (sec) 60 0 = disable or 10 to 86400
Table D-11. GPS and DTI Port Alarm Parameters
Description Default Value Value Range (seconds)
Port 1 thru 12 – FER Interval 10 0 = Disable, 1 to 1000
Port 1 thru 12 – Jitter Interval 10 0 = Disable, 1 to 1000
Port 1 thru 12 – MTIE-t Interval 35 0 = Disable, 1 to 1000
Port 1 thru 12 – FER Set Threshold (E-04) 100 0 = Disable, 5 to 10000
Port 1 thru 12 – FER Clear Threshold (E-04) 10 0 = Disable, 5 to 10000
Port 1 thru 12 – P-P_Jitter Set Threshold (pS) 8000 0 = Disable, 5000 to 10000000
Port 1 thru 12 – P-P_Jitter Clear Threshold (pS) 5000 0 = Disable, 5000 to 10000000
Port 1 thru 12 – MTIE-35 Set Threshold (pS) 10000 0 = Disable, 5000 to 10000000
Port 1 thru 12 – MTIE-35 Clear Threshold (pS) 7000 0 = Disable, 5000 to 10000000
Port 1 thru 12 – MTIE-t Set Threshold (pS) 10000 0 = Disable, 5000 to 10000000
Port 1 thru 12 – MTIE-t Clear Threshold (pS) 7000 0 = Disable, 5000 to 10000000
Note: For 8-port IOC module option, these parameters apply to Ports
1 thru 6, Port 11, and Port 12
Table D-10. IMC and Communication Parameters (Continued)
Description Default Value Value Range