097-93100-01 Revision C – February, 2010 TimeCreator 1000 Users Guide 65
Chapter 4 General Guidelines for using the Symmetricom TimeCreator 1000
DHCP
Since the unit only sets the time once, the time could be off by more than 100 ms if
this procedure is not followed.
DHCP
This unit's DHCP client will not continually attempt to acquire an IP address if the
Ethernet cable is not connected at power up, or when DHCP mode is enabled.
After the cable is connected, enter the following commands to restart DHCP:
set ip-state eth0 disable
set ip-state eth0 enable
CLI commands
Logging In And Out
At the login prompt, enter the user name. At the password prompt, enter the
password. The default administrator user name is “admin” with password
“SymmTC1000”.
To logout, use the command “logout”:
Example
Type
logout and press Enter.
Adding And Deleting Users
Only an administrator-level user can add or delete users.
Additional users can be added with the
set user command
Note: The "sync tod-source now" command used in some of the
following examples forces the TimeCreator 1000 to immediately start
using the new reference for time and frequency. This command is
useful in lab tests, but its use should be carefully planned since it may
cause cable modems to resync.

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals