90 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Chapter 5 Provisioning
Provisioning the Input Reference
Example
To provision the TimeCreator 1000 to set a GPS reference for manual mode and
specify the position as a latitude of N37.22.45.123, longitude of W121.55.36.123,
height of 17.5 meters, with a mask of 25 degrees, perform the following steps:
1. Login at the Admin or Power-User level (see Login, on page 74).
2. Type the command show
show tod-source to verify that the TOD source has
been set to GPS.
If the TOD source is set to GPS, proceed to step 3. If the the TOD source is not
set to GPS, type the command
set tod-source gps and press Enter
3. Type
set interface state gps enable and press Enter.
4. Type
set gps mode manual position n37:22:45.123 w121:55:36.123
17.5 mask 25
and press Enter.
Setting the DTI Parameters
DTI references connect to ports A and B. When you provision DTI as a reference
(TOD-source set to DTI), you must set ports A and B for client mode and enable
these ports. You can also set a priority value for each port.
Example
To provision ports A and B for DTI reference, set port A for a priority of 1 and port B
for a priority of 2 then perform the following steps:
1. Login at the Admin or Power-User level (see Login, on page 74).
2. Type the command show
show tod-source and press Enter to verify that the
TOD source has been set to DTI. This must be set before the state or type can be
set.
If the TOD source is set to DTI, proceed to step 3. If the the TOD source is not set
to DTI, type the command
set tod-source dti and press Enter
3. Type
set interface type portA client and press Enter.
4. Type
set interface type portB client and press Enter.
5. Type
set interface priority portA 1 and press Enter.
6. Type
set interface priority portB 2 and press Enter.
7. Type
set interface state port 11 enable and press Enter.