EasyManuals Logo

Symmetricom TimeCreator 1000 User Manual

Symmetricom TimeCreator 1000
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
162 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix A Alarms, Events and SNMP Traps
SNMP Traps
.
Table A-9. TimeCreator Events Traps - Additional Details
OID
Index
(y)
Trap OID Name Description Bindings Severity
1 trapIOCReset
(id = 1)
IOC <#> Module
reboot
trapID: IOCRST nonalarm
trapAID1: 1 or 2,
IOC module id
trapAID2: n/a
trapState:
set (2)
trapValue: n/a
2 trapIOCFirmwareCopy
Fail
(id = 5)
Firmware copy
bwtween IOC
modules failed
trapID: COPYFAIL nonalarm
trapAID1: n/a
trapAID2: n/a
trapState:
set (2)
trapValue: n/a
3 trapIOCActive
(id = 6)
IOC <#> is the
active IOC module
IOC <#> is not
active IOC module
trapID: CARDACTV nonalarm
trapAID1: 1 or 2,
IOC module id
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
4 trapIOCStandby
(id = 7)
IOC <#> is the
standby IOC module
IOC <#> is not
standby IOC module
trapID: CARDSTBY nonalarm
trapAID1: 1 or 2,
IOC module id
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
5 trapIOCWarmup
(id = 8)
IOC <#> has
transitioned in to
Warm-up Mode
trapID: CLKWARM nonalarm
trapAID1: 1 or 2,
IOC module id
trapAID2: n/a
trapState:
set (2)
trapValue: n/a

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals