288 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix D Specifications and Factory Defaults
Factory Defaults
Table D-10 provides the IMC module and communication parameter factory default
values and range.
Port A Priority (input) 2 1 thru 5
Port B Priority (input) 3 1 thru 5
GPS State Disable Enable | Disable
GPS Priority 1 1 thru 5
GPS Position Mode Auto Auto | Manual
GPS Position Lat – 0:0:0.0
Long – 0:0:0.0
Elevation– 0.0 m
LAT = dd:mm:ss.ssN or
dd:mm:ss.ssS
LONG = dd:mm:ss.ssE or
dd:mm:ss.ssW
ELEV = +/-hhhh.h height
in meters
GPS Elevation Mask 10 0 to 45 degrees
Leapseconds 14 0 to 40
Table D-10. IMC and Communication Parameters
Description Default Value Value Range
TOD Source RTC RTC | USER | NTP | DTI | GPS
Local Time Offset 00:00 +/-hh:mm
EIA-232 Service Enable Enable | Disable
Telnet Service Enable Enable | Disable
SSH Service Enable Enable | Disable
SNMP Service Enable Enable | Disable
NTP Service Enable Enable | Disable
SYSLOG Service Enable Enable | Disable
User #1 Access level 3 1 | 2 | 3
User #1 UserName admin
User #1 Password SymmTC1000
Eth0 IP mode Static Static|DHCP
Table D-9. GPS and DTI Port Parameters (Continued)
Description Default Value Value Range