Appendix A Alarms, Events and SNMP Traps
Event Messages
Event Messages
Table A-3 below provides a list of event messages and a description of each
message.
.
Note: You can display the events and alarms on a terminal or
computer running terminal emulation by entering the
Show
Alarm
command. Refer to Show Alarms, on page 178 and
Establishing a Connection to the TimeCreator 1000, on page 72 for
further details.
Table A-3. System Notification Messages - Events
Index
Trap Name
(trapID)
Severity
Trap Messages
(trapDescription)
Description
Corrective
Action
1 IOCRST nonalarm IOC <#> Module
reboot
Indicates that IOC
module has
rebooted
No action
required
2 COPYFAIL nonalarm Firmware copy
between IOC
modules failed
Indicates that the
Firmware copy
between IOC
modules has failed
No action
required
3 CARDACTV nonalarm IOC <#> is the
active IOC module
Indicates that IOC
module became
active
No action
required
IOC <#> is not
active IOC module
Indicates that IOC
module became
standby
No action
required
4 CARDSTBY nonalarm IOC <#> is the
standby IOC
module
Indicates that IOC
module became
standby
No action
required
IOC <#> is not
standby IOC
module
Indicates that IOC
module became
active
No action
required
5 CLKWARM nonalarm IOC <#> has
transitioned into
Warm-up Mode
Indicates that IOC
module has entered
into Warm-up mode
No action
required
6 CLKFREE nonalarm IOC <#> has
transitioned into
Free-run Mode
Indicates that IOC
module has entered
into Free-run mode
No action
required