097-93100-01 Revision C – February, 2010 TimeCreator 1000 Users Guide 137
Appendix A Alarms, Events and SNMP Traps
Alarm Messages
20 PWRFANFAIL Major Power Module
<#> fan failure
The fan of power
module A or B
failed
Check fan and if
not spinning or
alarm persists
then replace
power module
Power Module
<#> fan failure
cleared
The fan of power
module A or B is
ok
No action required
21 NOIOC Minor No IOC module
in system
Both IOC
modules are
removed
Insert IOC module
One or more IOC
modules in
system
At least one IOC
module in the
system
No action required
22 JAMSYNC Minor Jam sync
required
Need to jam
sync the IOC
module
Run the "sync
TOD-source now"
command
Jam sync
completed
Jam sync of IOC
module is
completed
No action required
23 DCMUNLOCK Major IOC <#> DCM
unlocked
Distributed clock
module has
become
unlocked
Hardware failure,
contact
Symmetricom tech
support
IOC <#> DCM
locked
Distributed clock
module has
become locked
No action required
24 PLLUNLOCK Major IOC <#> PLL
unlocked
Phase clock
module has
become
unlocked
Hardware failure,
contact
Symmetricom tech
support
IOC <#> PLL
locked
Phase clock
module has
become locked
No action required
Table A-2. System Notification Messages - Alarms (Continued)
Index
Trap Name
(trapID)
Severity
(default)
Trap Messages
(trapDescription)
Description
Corrective
Action

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals