154 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix A Alarms, Events and SNMP Traps
SNMP Traps
8 trapIOCInputDisqualified
(id = 29)
GPS reference
is
qualified/disqual
ified as system
reference for
IOC <#>
DTI Port <#>
reference is
qualified
/disqualified as
system
reference
BITS Port <#>
reference is
qualified
/disqualified as
system
reference
trapID: INPDISQ Minor
trapAID1: 0: GPS
1: input port A
2: input port B
3: BITS port 1
4: BITS port 2
trapAID2: 1 or 2,
IOC module id
trapState: clear (1),
set (2)
trapValue: n/a
9 trapIOCIncompatible
(id = 32)
IOC 1, IOC 2
incompatible
IOC 1, IOC 2
compatible
IOC 2, IOC 1
incompatible
IOC 2, IOC 1
compatible
trapID: IOCINCOMP Minor
trapAID1: 1 or 2,
IOC module id
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
10 trapIOCExtendedHoldover
(id = 34)
IOC <#> has
been in
Holdover Mode
for extended
period
IOC <#> has
transitioned out
of extended
Holdover Mode
trapID: CLKEXTHOLD Critical
trapAID1: 1 or 2,
IOC module id
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
Table A-6. TimeCreator 1000 Alarm Traps - Additional Details (Continued)
OID
Index
(x)
Trap OID Name Description Bindings
trapSev
erity

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals