097-93100-01 Revision C – February, 2010 TimeCreator 1000 Users Guide 169
Appendix A Alarms, Events and SNMP Traps
SNMP Traps
34 trapGPSCRCError
(id = 59)
GPS CTS CRC error
occurred
GPS CTS CRC error
cleared
trapID: GPSCRC nonalarm
trapAID1: n/a
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
35 trapOutputRootRecover
y
(id = 61)
Output Port <#>
entered <#>
recovery
Output Port <#>
exited <#> recovery
trapID: OUTRREC nonalarm
trapAID1: port #
trapAID2: 1: bridging
2: normal
holdover
3: extended
holdover
4: exceptional
holdover
5: exceptional
holdover
trapState: clear (1),
set (2)
trapValue: n/a
36 trapOutputRecoveryTim
eout
(id = 62)
Output Port <#>
recovery timeout
trapID: OUTRTOUT nonalarm
trapAID1: port #
trapAID2: n/a
trapState:
set (2)
trapValue: n/a
37 trapAuthorizationGrant
ed
(id = 301)
<#> authorization
granted
trapID: AUTHGRN nonalarm
trapAID1: n/a
trapAID2: n/a
trapState:
set (2)
trapValue: user name
Table A-9. TimeCreator Events Traps - Additional Details (Continued)
OID
Index
(y)
Trap OID Name Description Bindings Severity

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals