172 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix A Alarms, Events and SNMP Traps
SNMP Traps
48 trapPPJitterAlarm
(id = 323)
Port <#> P-P Jitter
threshold set to 0,
alarm disabled
Port <#> P-P Jitter
threshold set above
0, alarm enabled
trapID: PPJALA nonalarm
trapAID1: port #
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
49 trapFERAlarm
(id = 324)
Port <#> FER
threshold set to 0,
alarm disabled
Port <#> FER
threshold set above
0, alarm enabled
trapID: FERALA nonalarm
trapAID1: port #
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
50 trapPMPhaseData
(id = 325)
PM phase data lost
PM phase data
recovered
trapID: PHALOSS nonalarm
trapAID1: n/a
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
51 trapPMJitterData
(id = 326)
PM jitter data lost
PM jitter data
recovered
trapID: JITLOSS nonalarm
trapAID1: n/a
trapAID2: n/a
trapState: clear (1),
set (2)
trapValue: n/a
52 trapSystemTODSetByD
TI
(id = 328)
System TOD has
been set by root
server
trapID: SETBYDTI nonalarm
trapAID1: n/a
trapAID2: n/a
trapState:
set (2)
trapValue: n/a
Table A-9. TimeCreator Events Traps - Additional Details (Continued)
OID
Index
(y)
Trap OID Name Description Bindings Severity

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals