190 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix B Command Descriptions and Communications Interface
CLI Commands
Show Bridge-Time
This command displays the bridging time that is used when the system does not
have a qualified reference.
Command Syntax:
show bridge-time
Example:
tc1000>show bridge-time
Response:
Bridging Time - 900
Remarks: If the system does not qualify a TOD source (frequency reference) within
the specified bridging time, the system transitions to holdover mode.
Related:
set bridge-time
Level : User, Power-User and Admin
Set Bridge-Time
Use this command to provision the amount of time the system will remain in bridging
mode before transitioning into the holdover mode.
Command Syntax:
set bridge-time <value>
Example:
To set the bridge time to a value of 1000 seconds -
tc1000>set bridge-time 1000
Remarks: The default value is 900 seconds. Based on DOCSIS requirements and
the characteristics of the TimeCreator 1000 oscillator, impairments in performance
are not expected within this default time period.
The range for this parameter is 100 100000 seconds
Related:
show bridge-time
Level : Power-User and Admin only

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals